Specifications
| Size | 350.5mm(W)*400.5mm(L)*195.5mm(H) |
| Weight | ≤9kg |
| Max Power Consumption | <20w |
| Leakage Current | <5mA |
| Application technique | Ultra-wideband pulse microwave reflection method and thermal conductivity method |
| Detectable container material | can detect different materials such as aluminum, glass and ceramic packaging liquid |
| Detectable container specification | 1.Plastic/glass/Ceramics: Volume :≥100ml,Height:≥3cm Diameter:>30mm <200mm Max height: unlimited Wall Thickness :≤0.5mm 2.Metal container: Volume:≥100ml,Height:≥3cm Diameter:>30mm <150mm Max height: unlimited Wall Thickness :≤0.5mm |
| Detector liquid | The instrument is capable of alarming flammable or dangerous liquids in the following sealed containers: 93 # gasoline, kerosene, diesel, ether, isopropyl ether, petroleum ether, acetaldehyde, ethylene glycol, nitrobenzene, propylene oxide, n-heptane , Perfume, acetone, benzene, toluene, xylene, dichloroethane, trichloromethyl, tetrahydrofuran, paint, n-hexane, hydrochloric acid, sulfuric acid, nitric acid and the like. |
| Liquid detection | ≥100ml,height≥3cm |
| Start-up time | 2.3S, no warm |
| Analyze Timing | Insulated container(Plastic, glass, ceramic container):<1S Conductive container(Aluminum cans,iron cans):<5S |
| Alarm | Sound, light, liquid crystal display |
| Database Storage | Up to 10000 times detection stored automatically, enable transferring to USB disk. |
| Language | Chinese system & English system (optional) |
| Adjustable brightness | The screen brightness can be adjusted |
| Parameter setting | It is convenient for the after-sales engineer to set the working parameters of the liquid detector according to the specific environment. |
| Adjustable precision | The recognition accuracy of software is adjusted by setting numerical value |
| Self-checking function | The instrument has the function of self-calibration of the equipment, which can prevent the occurrence of a large amount of false alarm |
| Operating temperature & humidity | -10℃-55℃; 0%-90% |
| Working voltage | AC 180V-240V(50/60Hz) |
| Atmosphere pressure | 86kPa-106kPa |